B Series Rail-mounted Transmitter
Summary:
Keywords:
Category:
Detailed introduction
Product Features
- Three-terminal isolation enhances anti-interference capability, ensuring stable, reliable, and high-precision measurement performance.
- Modbus digital communication enhances resolution and enables the acquisition of sensor data for batch production recording, thereby better meeting compliance requirements. Remote calibration via Modbus RTU, along with one-touch calibration functionality, simplifies PLC programming while delivering higher accuracy.
- A dedicated 3-in-1 design for the fermentation industry allows even non-temperature-compensated pH electrodes (such as AK9 or 58-interface pH electrodes) to leverage the fermentation-specific PT100 temperature sensor for humidity compensation of pH and/or DO measurements, thereby enhancing measurement accuracy.
Technical Specifications
| Product Name | B-Series Rail-Mounted Transmitter |
| Power supply | 24 VDC, <2 W |
| Current output: 4–20 mA | 0.02 mA / 3.8–20.5 mA (meets NE43 requirements) |
| Modbus | 9600bps |
| Ambient temperature | -10 to 50 °C |
| Relative humidity | 0 to 95% no cooling |
| Ion electrode | Stability/Resolution/Range |
| pH | 0.02/0.01/0 to 14 pH |
| ORP | 1/1/-2000 to 2000 mV |
| Temperature range | 0.3%FS/0.1/-10 to 150 °C |
| Temperature sensor | PT100 0.2/0.01/0-150° PT1000 (optional) 0.1/0.01/0–150 ° |
| pH Calibration (Modbus) | 1 o'clock, 2 o'clock, 3 o'clock, process |
| ORP Correction (Modbus) | 1 o'clock, process |
| Electrical Conductivity/Resistivity | Stability/Display Resolution/Range |
| 2e Non-Ultra-Pure Water Applications | 0.5%/0.01 µS/cm/1–2000 µS/cm |
| 2e Ultrapure Water Applications | 0.5%/0.01 µs/0–2000 µS/cm, depending on the electrode constant; |
| 4e | 0.5%/0.01 µs/5 µs/cm – 500 ms/cm, also dependent on the electrode constant. |
| Temperature range | 0.3%FS/0.1/-10 to 150°C |
| Temperature sensor | PT1000, custom-made |
| Correction | 1 o'clock, 2 o'clock, the process |
| Temperature compensation | (Ultra) pure water, linear, none |
| Dissolved oxygen electrode | Stability/Resolution/Range |
| ppm DO | 0.2%/0.1%/0 to 400% air |
| Temperature measurement range | 0.3%FS/0.1/-10 to 80°C |