FE931 Clamp-on Ultrasonic Flow Meter
Summary:
The clamp-on ultrasonic flow meter employs the time-of-flight ultrasonic measurement principle to achieve precise measurement of fluid flow in pipelines. The product features an integrated clamp-on design, making installation simple and convenient; the installation process requires no contact with the fluid medium and does not necessitate shutdowns or production interruptions.
Keywords:
Category:
The clamp-on ultrasonic flow meter employs the time-of-flight ultrasonic measurement principle to achieve precise measurement of fluid flow in pipelines. The product features an integrated clamp-on design, making installation simple and convenient; the installation process requires no contact with the fluid medium and does not necessitate shutdowns or production interruptions.
Detailed introduction
Product Features
- Easy installation—no pipe cutting required.
- No adjustment required—deduction and measurement occur simultaneously.
- LCD color display with 4-way adjustable screen rotation.
- The clamp-on ultrasonic flow meter employs the time-difference method for measurement, enabling installation in just four simple steps without the need to cut or disrupt the pipeline. The measurement process is non-contact, requiring no contact with the fluid medium and no shutdown of operations.
- The product is standardly equipped with an RS485 communication interface commonly used in industrial settings, supports the MODBUS protocol, and enables remote monitoring and data transmission of the instrument.
Technical Specifications
Product Name | FE931 |
Flow rate range | 0.3 m/s ~ 5.0 m/s |
Accuracy | ±3% of FS |
Pipe diameter specifications | DN15, DN20, DN25, DN32, DN40, DN50 |
Measurement medium | Water |
Piping | Stainless steel, PVC, copper, PPR |
Communication Interface | RS485; supports MODBUS protocol |
Output | 4–20 mA, maximum load 500 Ω, with isolation |
Power supply | 10–36 VDC/500 mA |
Keyboard | 3 touch buttons |
Display screen | 1.54-inch color LCD screen, resolution 240×240 |
Temperature | Transmitter installation ambient temperature: -10°C to 50°C |
Humidity | Relative humidity: 0–99%, no condensation |
Protection Level | IP54 |
Housing material | PC engineering plastic |
Clamp material | PC engineering plastic |
Transmitter | Integrated |
Sensor | clamp-on type |
Cable | φ5 six-core cable, equipped with a self-locking connector, standard length 4 m. |
Industry Applications
| New energy and liquid cooling fields | Device Traffic Monitoring | Water Industry Management | Building condensate |
|
| ![]() | ![]() |
Pipe Size and Measurement Range
| Piping | Nominal Internal Diameter of Pipe | Pipe clamp outer diameter range (mm) | Flow range (m³/h) | |
| Grade A | Grade B | |||
Stainless steel
| DN15 | 18.5~22.5 | / | 0.2~3.5 |
| DN20 | 24~29 | 22.5~27.5 | 0.4~6 | |
| DN25 | 30.5~35.5 | 29–34 | 0.5~9 | |
| DN32 | 37.5~42.5 | 36~41 | 0.9~15 | |
| DN40 | 49.5~54.5 | 48~53 | 1.3~23 | |
| DN50 | 58.5~63.5 | 57~62 | 2.0~35 | |
Installation Method
Step 1: Clean the pipeline Perform surface treatment on the pipeline to thoroughly remove loose paint, rust, dirt, and other contaminants from the surface. | Step 2: Install the pipe clamp Clamp the upper and lower pipe clamps onto the selected pipe location. If loosening is detected, affix adhesive pads to the inner wall of the lower clamp to enhance the clamping force. | Step 3: Tighten the screw Tighten the four screws connecting the upper and lower pipe clamps securely to ensure stability and prevent any looseness. | Step 4: Power on to begin measurement. The actual pipe outer diameter, wall thickness, and material parameters can be adjusted via the “Pipeline Parameter Settings” menu item to ensure measurement accuracy. |
![]() | ![]() | ![]() | ![]() |