FE550 Split-type Flange Electromagnetic Flow Meter
Summary:
Electromagnetic flowmeters are designed based on Faraday’s law of electromagnetic induction to directly measure the instantaneous flow rate of conductive liquids in closed pipelines and feature flow accumulation functionality. In addition to on-site monitoring and display, they can output standard current signals, pulse signals, and RS485 digital signals for recording, adjustment, and control, thereby enabling automated process monitoring and control. These instruments are widely used in industries such as municipal water supply, chemical processing, coal mining, environmental protection, light industry and textiles, metallurgy, and papermaking.
Keywords:
Category:
Electromagnetic flowmeters are designed based on Faraday’s law of electromagnetic induction to directly measure the instantaneous flow rate of conductive liquids in closed pipelines and feature flow accumulation functionality. In addition to on-site monitoring and display, they can output standard current signals, pulse signals, and RS485 digital signals for recording, adjustment, and control, thereby enabling automated process monitoring and control. These instruments are widely used in industries such as municipal water supply, chemical processing, coal mining, environmental protection, light industry and textiles, metallurgy, and papermaking.
Detailed introduction
Product Features
- Reliable measurement, high accuracy, and excellent stability.
- Integrated design with no moving parts, easy installation, and maintenance-free.
- RS485 communication interface—standard Modbus RTU protocol.
- Unaffected by fluid flow direction; accurate measurement in both forward and reverse directions.
- Employs advanced low-frequency square-wave excitation, ensuring zero-point stability, strong anti-interference capability, and reliable operation.
- The orientation of the display header and the display interface can both be adjusted for easy reading.
- Built-in Chinese–English bilingual support with free switching.
Technical Specifications
| Product Name | FE550 Split-type Flange Electromagnetic Flow Meter | |||
| Measurement variable | Directly measured variable: flow velocity Measured variable calculated values: volumetric flow rate, mass flow rate | |||
| Flow rate range | Typical flow velocity range: 0.5 m/s to 5 m/s | |||
| Nominal diameter | DN10~DN1000 | |||
| Turndown ratio | 1:10 | |||
| Current Output | Function | Flow velocity, volumetric flow rate, or mass flow rate (under the condition of constant density of the measured medium) | ||
| Scope | Scope | (4–20) mA | ||
| Upper range limit | 20mA | |||
| Lower limit of range | 4mA | |||
| Internal voltage | 24VDC | |||
| Load | ≤750Ω | |||
| Pulse output | Function | Can be configured as a pulse output. | ||
| Pulse output | Basic | Output pulse width: 0.1 ms to 2000 ms (this value is below the maximum duty cycle, which is 1:1). Fmax ≤ 5000 cp/s | ||
| Pulse coefficient | 0.001~100,000 per unit | |||
| Passive | U external ≤ 30 VDC | |||
| Active | Internal active output voltage U ≤ 24 VDC | |||
| Active output current I ≤ 4.52 mA | ||||
| Communication Output | RS485 interface, MODBUS-RTU communication protocol | |||
| Relay Output (Separate Option) | 2-way SPST, rating 250VAC, 3A | |||
| Power supply | AC: 100 VAC to 240 VAC, 50/60 Hz; DC: 20 VDC ~ 28 VDC | |||
| Power consumption | ≤15W | |||
| Terminal block | Screw-type terminal block | |||
| Electrical Interface | M20*1.5 cable plug | |||
| Signal cable | Applicable only to split-type models; standard cable length is 10 m, with other lengths available upon request. | |||
| Refer to working conditions | Medium: Water Temperature: 20°C Pressure: 0.1 MPa Installation requirements: upstream straight pipe section: ≥10DN; downstream straight pipe section: ≥5DN. | |||
| Accuracy | ±0.5% of the measured value (flow velocity range: 0.5 m/s to 5 m/s) | |||
| Repeatability | 0.16% | |||
| Flow rate–velocity characteristic curve |
①X[m/s]: Flow velocity ②Y[%]: Deviation of the actual measured value (mV) | |||
| Medium temperature | Neoprene lining: -10°C to 70°C Polyurethane rubber lining: -10°C to 60°C PTFE/FEP Lining: -10°C to 120°C PFA Lining: -10℃~120℃ | |||
| Rated pressure (high pressure customizable) | DN10–DN250: PN < 1.6 MPa DN300–DN1000: PN < 1.0 MPa Note: For individual specification selections that differ, the nameplate shall prevail; high-pressure options are available for customization. | |||
| Electrical conductivity | ≥50 μS/cm | |||
| Buryability | <5 m (split-type sensor with IP68 protection only) | |||
| Immersion depth | <3 m (split-type sensor with IP68 protection only) | |||
| Ambient temperature | -10℃~55℃ | |||
| Storage temperature | -20℃~55℃ | |||
| Protection Level | Standard type: IP65 High-protection type: IP66/IP67 (Cable requirements: Select armored shielded cable, with conductor configuration of 2×2×0.75 or 1.5×2/2.5×2, and cable diameter of 8 mm to 12 mm). | |||
Industry Applications
| Environmental protection industry | Building Heating | Industrial Automation | Municipal Water Services |
|
| ![]() | ![]() |
The previous one
Next
The previous one
Next
Product Inquiry
Attention: Please leave your phone number or email address, and our professionals will contact you as soon as possible!
Related products