CY231 Differential Pressure Mass Flow Meter
Summary:
The CY231 series flow meters operate on the differential-pressure principle, calculating flow rate by measuring the pressure difference generated as the fluid passes through a throttling element. As the fluid flows through the pipe and encounters the throttling element, its velocity increases and its static pressure decreases, creating a pressure differential across the element. A sensor measures this differential pressure, converts it into an electrical signal, and outputs the signal. The controller then processes the output differential-pressure signal using the flow equation (the Hagen–Poiseuille equation) to determine the fluid flow rate. The CY231 can measure multiple parameters, including gas mass flow, volumetric flow, pressure, and temperature, and transmits these parameters via communication interfaces such as RS485 and RS232 to a touch screen or other external devices and control systems for display, enabling data monitoring and analysis.
Keywords:
Category:
The CY231 series flow meters operate on the differential-pressure principle, calculating flow rate by measuring the pressure difference generated as the fluid passes through a throttling element. As the fluid flows through the pipe and encounters the throttling element, its velocity increases and its static pressure decreases, creating a pressure differential across the element. A sensor measures this differential pressure, converts it into an electrical signal, and outputs the signal. The controller then processes the output differential-pressure signal using the flow equation (the Hagen–Poiseuille equation) to determine the fluid flow rate. The CY231 can measure multiple parameters, including gas mass flow, volumetric flow, pressure, and temperature, and transmits these parameters via communication interfaces such as RS485 and RS232 to a touch screen or other external devices and control systems for display, enabling data monitoring and analysis.
Detailed introduction
Product Features
- No “specific heat capacity” error; high-precision data with real-time feedback
- Employs a DSP-based main controller to further enhance precision and reliability.
- Compact design for a more intuitive large-screen experience
- Switch freely among nearly 100 gases—no need to return the instrument to the factory for calibration.
- Supports multi-parameter measurement for convenient data analysis
- Supports USB Type-C and Bluetooth, enabling flexible and versatile device connectivity.
Technical Specifications
Product Name | CY231 Differential Pressure Mass Flow Meter |
Measurement range | 2 SCCM to 3000 SLM |
Flow measurement range ratio | 100:1 |
Accuracy | ±0.5% of full scale |
Linear | ±0.5% F.S. |
Repeatability | ±0.2% F.S |
Stability | <±0.1%F.S |
Response time | 50mS |
Temperature coefficient | ±0.015% F.S./°C |
Operating temperature | -10℃ to 60℃ |
Work stress | Operating pressure differential: 0.05–0.5 MPa |
Maximum withstand voltage | 1MPa |
Leak rate | 1 × 10 Pa·m/s |
Base material | Stainless steel |
Joint | VCR, ferrule, quick-connect fitting, tower fitting, and flange installation |
Sealing material | Fluororubber, nitrile rubber, perfluoroether, ethylene propylene diene monomer |
Enclosure Protection Rating | IP40 |
Installation Location | Horizontal installation |
Monochrome LED display | Display flow rate and setpoint simultaneously. |
Electrical Connection | DB9 port, RJ11, 5.5×2.1 power quick-connect |
Display Status | With LCD display, without LCD display |
Digital quantity | Modbus protocol (RS232/485), ProfiBus protocol, DeviceNet protocol |
Analog quantity | 0–5 V, 4–20 mA, 1–5 V |
Power supply | ±15 VDC, 24 VDC |